Technical Configuration (Digital Voips)

MultiVOIP User Guide

 

 

T1 Parameter Definitions (cont’d)

Field Name

Values

Description

Line Build Out

0 dB, -7.5 dB,

To reduce the crosstalk on received

 

-15 dB, -22.5 dB

signals, a transmit attenuator can

 

 

be placed in the data path.

 

 

Transmit attenuation is selectable.

 

 

Default: O dB

 

 

 

Pulse Shape

0 to 40 Meters

Refers to length of cable

Level

40 to 81 m

between MultiVOIP and

 

81 to 122 m

PBX/telco in meters. Most

 

122 to 162 m

common will be 0 to 40m.

 

162 to 200 m

 

 

 

 

Clocking

External/Internal

Set opposite to telco/PBX setting.

 

 

Example: if telco clocking internal,

 

 

set VOIP clocking as external.

 

 

 

Line Coding

AMI / B8ZS

Match to PBX or telco.

 

 

 

PCM Law

A-Law/Mu-Law

Match to PBX or telco. “

 

 

Mu-law” is analog-to-digital

 

 

compression/expansion

 

 

standard used in North America.

 

 

“A-law” is European standard.

 

 

 

Yellow Alarm

Bit 2 / 1111…

Depending on the Frame Format

Format

 

used, there are choices of Yellow

 

 

Alarm format, as follows:

 

 

D4: -Bit2= 0 in every speech

 

 

channel

 

 

-FSbit of frame 12 is forced to

 

 

one.

 

 

ESF: -Bit2= 0 in every speech

 

 

channel

 

 

–1111111100000000 pattern in

 

 

data link channel.

 

 

Check with your PBX/telco

 

 

administrator for the correct setting

 

 

or use the default value (1111 … ).

 

 

 