Technical Configuration (Analog/BRI)

MultiVOIP User Guide

 

 

FXS Loop Start Interface: Parameter Definitions

Field Name

Values

Description

Message

Y/N

Applicable only when MultiVOIP

Waiting Light

 

is used with Avaya Magix PBX

 

 

units equipped with Merlin

 

 

Messaging Centralized mail.

 

 

When enabled, the Message

 

 

Waiting Light feature allows the

 

 

PBX to send mode-codes and

 

 

message-waiting indications to

 

 

another Avaya Magix PBX, which

 

 

in turn will turn on the message

 

 

waiting light on a phone station. It

 

 

also allows Direct Inward Dialing,

 

 

such that no additional dial tone is

 

 

needed on voip call.

 

 

 

Ring Count,

integer values

Maximum number of rings that the

FXS

 

MultiVOIP will issue before giving

 

up the attempted call.

 

 

FXS Options,

Y/N

When enabled, the MultiVOIP will

Current Loss

 

interrupt loop current in the FXS

 

circuit to initiate a disconnection.

 

 

 

 

This tells the device connected to

 

 

the FXS port to hang up. The

 

 

Multi-VOIP cannot drop the call;

 

 

the FXS device must go on hook.