T1 Statistics: Field Definitions (cont’d)

 

 

 

 

 

 

 

Field

Values

Description

 

 

Name

 

 

 

 

 

 

 

 

 

Bipolar

Integer tally of

Two successive pulses of the same polarity

 

Violation

violation count

have been received and these pulses are not

 

 

part of zero substitution. On an AMI-encoded

 

 

 

since last reset.

 

 

 

line, this represents a line error. On a B8ZS

 

 

 

 

 

 

 

 

line, this may represent the substitution for a

 

 

 

 

string of 8 zeroes.

 

 

Receive Slip

Tally since last

A receive slip (positive or negative) has

 

 

 

reset.

occurred. Slips indicate a clocking mismatch

 

 

 

 

(or lack of synchronization) between T1/E1

 

 

 

 

devices. When slips occur, data may be lost or

 

 

 

 

repeated.

 

 

 

 

 

 