Operation & Maintenance

MultiVOIP User Guide

 

 

 

 

 

 

 

 

 

 

 

 

E1 Statistics: Field Definitions (cont’d)

 

 

 

 

 

 

 

Field

Values

Description

 

 

Name

 

 

 

 

 

 

 

 

 

Receive

 

The framing pattern '0000' in 2 consecutive

 

 

Timeslot 16

 

CAS multiframes were not found or in all time

 

 

Loss of

 

slot 16 of the previous multiframe all bits were

 

 

MultiFrame

 

reset.

 

 

Alignment

 

 

 

 

 

 

 

 

 

Transmit Line

 

At least 32 consecutive zeroes were

 

Open

 

transmitted.

 

 

 

 

 

 

 

Transmit Data

 

For use by MTS Technical Support

 

Underrun

 

Personnel.

 

 

 

 

 

 

 

Transmit Slip

 

The frequency of the transmit clock is greater

 

Negative

 

than the frequency of the transmit system

 

 

 

interface working clock. A frame is skipped.

 

 

 

 

 

 

Bipolar

Integer tally of

Bipolar Violation (or BPV) refers to two

 

 

Violation

violation count

successive pulses of the same polarity on the

 

 

E1 line. On an AMI-encoded line, this

 

 

 

since last reset.

 

 

 

represents a line error. On a B8ZS line, this

 

 

 

 

 

 

 

 

may represent the substitution for a string of 8

 

 

 

 

zeroes.

 

 

Excessive

Tally since last

Displayed value will increment if consecutive

 

 

Zeroes

reset.

zeroes beyond a set threshold are detected.

 

 

 

 

I.e., tally increments if more than 7

 

 

 

 

consecutive zeroes in the received data stream

 

 

 

 

are detected under B8ZS line coding, or if 15

 

 

 

 

consecutive zeroes are detected under AMI

 

 

 

 

line coding.

 

 

 

 

 

 

 

Transmit Slip

Tally since last

Slip in transmitted data stream. Slips indicate

 

 

 

reset.

a clocking mismatch (or lack of

 

 

 

 

synchronization) between T1/E1 devices.

 

 

 

 

When slips occur, data may be lost or

 

 

 

 

repeated.

 

 

 

 

 

 

 

Receive Slip

Tally since last

Slip in received data stream. Slips indicate a

 

 

 

reset.

clocking mismatch (or lack of synchronization)

 

 

 

 

between T1/E1 devices. When slips occur, data may

 

 

 

 

be lost or repeated.

 

 

 

 

 

 