4.Terminal Mode. When a voip ISDN connector is to be connected to a PBX extension line or to a telco line, select “Terminal” as the

“Layer 1 Interface” in the ISDN Parameters screen. When making cable connections, an NT1 device will be needed between the MultiVOIP and the PSTN or between the MultiVOIP and any PBX with a “U” interface. (For more information, see Appendix B: Cable Pinouts in this manual.) Connect cables between voip ISDN connectors and network equipment.

NOTE: In order to operate in Terminal mode, the network equipment to which you will be connecting (e.g., PBX) must support D-channel signaling in its ISDN-S/T interface.