Multi-Tech Systems MVP-2400 manual MultiVOIP User Guide Technical Configuration Analog/BRI, 249

Models: MVP-3010 MVP-2400 MVP-2410

1 605
Download 605 pages 56.98 Kb
Page 249
Image 249

MultiVOIP User Guide

Technical Configuration (Analog/BRI)

 

 

The Custom Tone-Pair Settings fields are described in the table below.

Custom Tone-Pair Settings Definitions

Field Name

Values

Description

 

 

 

Tone Pair

dial tone,

Identifies the type of telephony

 

busy tone,

signaling tone for which frequencies

 

ring tone,

are being specified.

 

‘unobtainable’

 

 

tone,

 

 

survivability tone,

 

 

re-order tone

 

TONE PAIR

VALUES

About Defaults: US telephony

 

 

values are used as defaults on this

 

 

screen. However, since this dialog

 

 

box is provided to allow custom

 

 

tone-pair settings, default values are

 

 

essentially irrelevant.

Frequency 1

frequency in Hertz

Frequency of lower tone of pair.

 

 

This outbound tone pair enters the

 

 

MultiVOIP at the input port.

 

 

 

Frequency 2

frequency in Hertz

Frequency of higher tone of pair.

 

 

This outbound tone pair enters the

 

 

MultiVOIP at the input port.

 

 

 

Gain 1

gain in dB

Amplification factor of lower

 

+3dB to –31dB

frequency of pair. This figure

 

describes amplification that the

 

and “mute” setting

 

MultiVOIP applies to outbound

 

 

 

 

tones entering the MultiVOIP at

 

 

the input port. Default = -16dB

Gain 2

gain in dB

Amplification factor of higher

 

+3dB to –31dB

frequency of pair. This figure

 

and “mute” setting

describes amplification that the

 

 

MultiVOIP applies to outbound

 

 

tones entering the MultiVOIP at

 

 

the input port. Default = -16dB

 

 

 

249

Page 249
Image 249
Multi-Tech Systems MVP-2400, MVP-2410, MVP-3010 manual MultiVOIP User Guide Technical Configuration Analog/BRI, 249