Operation & Maintenance

MultiVOIP User Guide

 

 

 

 

 

 

 

 

 

 

 

 

T1 Statistics: Field Definitions (cont’d)

 

 

 

 

 

 

 

Field

Values

Description

 

 

Name

 

 

 

 

 

 

 

 

 

Yellow Alarm

Tally since last

The alarm signal sent by a remote T1/E1

 

 

 

reset.

device to indicate that it sees no receive signal

 

 

 

 

or cannot synchronize on the receive signal.

 

 

 

 

 

 

 

Frame Search

 

[To be supplied.]

 

Restart Flag

 

 

 

 

 

 

 

 

 

Loss of

Tally since last

In D4 or ESF mode, displayed value will

 

 

MultiFrame

reset.

increment if multiframe alignment has been

 

 

Alignment

 

lost or if loss of frame alignment has been

 

 

 

 

detected.

 

 

 

 

 

 

 

Transmit Slip

Tally since last

Slip in transmitted data stream. Slips indicate

 

 

 

reset.

a clocking mismatch (or lack of

 

 

 

 

synchronization) between T1/E1 devices.

 

 

 

 

When slips occur, data may be lost or

 

 

 

 

repeated.

 

 

 

 

 

 

 

Pulse Density

 

The pulse density of the received data stream

 

 

Violation

 

is below the requirement defined by ANSI

 

 

 

 

T1.403 or more than 15 consecutive zeros are

 

 

 

 

detected.

 

 

 

 

 

 

 

Line

 

The line loopback activation signal has

 

 

Loopback

 

been detected in the received bit stream.

 

 

Activation

 

 

 

 

Signal

 

 

 

 

 

 

 

 

 

Transmit Line

 

At least 32 consecutive zeros were

 

 

Open

 

transmitted.

 

 

 

 

 

 

 

Transmit Data

 

For use by MTS Technical Support

 

 

Underrun

 

Personnel.

 

 

 

 

 

 

 

Transmit Slip

 

The frequency of the transmit clock is

 

 

Negative

 

greater than the frequency of the transmit

 

 

 

 

system interface working clock. A frame

 

 

 

 

is skipped.

 

 

 

 

 

 