MultiVOIP User Guide

Mechanical Installation & Cabling

 

 

Connect one end of an RJ-11 phone cord to the Channel 1 FXS/FXO connector on the back of the MultiVOIP.

Connect the other end to the DID jack.

NOTE: DID lines are polarity sensitive. If, during testing, the DID line rings busy consistently, you will need to reverse the polarity of one end of the connector (swap the connections of the wires to the two middle pins of one RJ-11 connector).

6.Repeat the above step to connect the remaining telephone equipment to the second channel on your MultiVOIP.

7.Ensure that the unit is properly connected to earth ground by verifying that it is reliably grounded when mounted within a rack.

This can be accomplished by connecting a grounding wire between the chassis and a metallic object that will provide an electrical ground.

8.Turn on power to the MultiVOIP by placing the ON/OFF switch on the back panel to the ON position. Wait for the BOOT LED on the MultiVOIP to go off before proceeding. This may take a few minutes.

Proceed to the Software Installation chapter to load the MultiVOIP software.

107

Page 107
Image 107