Operation and Maintenance

MultiVOIP User Guide

 

 

 

 

 

 

 

 

 

 

 

 

E1 Statistics: Field Definitions (cont’d)

 

 

 

 

 

 

 

Field

Values

Description

 

 

Name

 

 

 

 

 

 

 

 

 

Receive

 

The framing pattern '0000' in 2

 

 

Timeslot 16

 

consecutive CAS multiframes were not

 

 

Loss of

 

found or in all time slot 16 of the previous

 

 

MultiFrame

 

multiframe all bits were reset.

 

 

Alignment

 

 

 

 

 

 

 

 

 

Transmit

 

At least 32 consecutive zeroes were

 

 

Line Open

 

transmitted.

 

 

 

 

 

 

 

Transmit

 

For use by MTS Technical Support

 

 

Data

 

Personnel.

 

 

Underrun

 

 

 

 

 

 

 

 

 

Transmit

 

The frequency of the transmit clock is

 

 

Slip

 

greater than the frequency of the transmit

 

 

Negative

 

system interface working clock. A frame

 

 

 

is skipped.

 

 

 

 

 

 

Bipolar

Integer tally of

Bipolar Violation (or BPV) refers to two

 

 

Violation

violation count

successive pulses of the same polarity on

 

 

 

since last reset.

the E1 line. On an AMI-encoded line, this

 

 

 

represents a line error. On a B8ZS line,

 

 

 

 

 

 

 

 

this may represent the substitution for a

 

 

 

 

string of 8 zeroes.

 

 

Excessive

Tally since last

Displayed value will increment if

 

 

Zeroes

reset.

consecutive zeroes beyond a set threshold

 

 

 

 

are detected. I.e., tally increments if more

 

 

 

 

than 7 consecutive zeroes in the received

 

 

 

 

data stream are detected under B8ZS line

 

 

 

 

coding, or if 15 consecutive zeroes are

 

 

 

 

detected under AMI line coding.

 

 

 

 

 

 

 

Transmit

Tally since last

Slip in transmitted data stream. Slips

 

 

Slip

reset.

indicate a clocking mismatch (or lack of

 

 

 

 

synchronization) between T1/E1 devices.

 

 

 

 

When slips occur, data may be lost or

 

 

 

 

repeated.

 

 

 

 

 

 

 

Receive Slip

Tally since last

Slip in received data stream. Slips indicate a

 

 

 

reset.

clocking mismatch (or lack of synchronization)

 

 

 

 

between T1/E1 devices. When slips occur, data

 

 

 

 

may be lost or repeated.

 

 

 

 

 

 

442

Page 442
Image 442
Multi-Tech Systems MVP-130/130FXS, MVP-410ST/810ST, MVP-2410/3010 manual 442