Multi-Tech Systems MVP-2410/3010, MVP-410ST/810ST, MVP-130/130FXS manual 260, Did Options cont’d

Models: MVP-410ST/810ST MVP-130/130FXS MVP-2410/3010

1 559
Download 559 pages 35.93 Kb
Page 260
Image 260

Technical Configuration (Analog/BRI)

MultiVOIP User Guide

 

 

DID Interface Parameter Definitions (cont’d)

Field Name

Values

Description

DID Options (cont’d)

 

 

 

 

Start Modes

Immediate Start,

For Wink Start, the voip detects

 

Wink Start,

the off-hook condition. Then

 

Delay Dial

the voip reverses battery

 

 

polarity for a specified time

 

 

(140-290 ms; a “wink”) and then

 

 

becomes ready to receive dial

 

 

digits.

 

 

For Delay Dial, the voip detects

 

 

detects the off-hook condition.

 

 

Then the voip reverses battery

 

 

polarity for a specified time

 

 

(reverse polarity duration has

 

 

wider acceptable range than for

 

 

Wink Start) and then becomes

 

 

ready to receive dial digits.

 

 

 

Wink Timer

integer values,

This is the length of the wink

(in ms)

in milliseconds

for Wink Start and Delay Dial

 

 

signaling modes..

 

 

Applicable only when Start

 

 

Mode parameter is set to “Wink

 

 

Start” or “Delay Dial.”

 

 

 

Dialing Options

 

Inter Digit

integer values,

This is the length of time that

Timer

in seconds

the MultiVOIP will wait

 

 

between digits. When the time

 

 

expires, the MultiVOIP will

 

 

look in the phonebook for the

 

 

number entered.

 

 

Default = 2.

 

 

 

Message

--

Not applicable to DID-DPO

Waiting

 

interface.

Indication

 

 

 

 

 

Inter-Digit

integer values,

This parameter is applicable

Regeneration

in milliseconds

when digits are dialed onto a

Timer

 

DID-DPO channel after the

 

 

connection has been made. The

 

 

length of time between the

 

 

outputting of DTMF digits.

 

 

Default = 100 ms.

 

 

 

260

Page 260
Image 260
Multi-Tech Systems MVP-2410/3010, MVP-410ST/810ST, MVP-130/130FXS manual 260, Did Options cont’d