Multi-Tech Systems MVP-410ST/810ST, MVP-130/130FXS, MVP-2410/3010 Common will be 0 to 40m, 159

Models: MVP-410ST/810ST MVP-130/130FXS MVP-2410/3010

1 559
Download 559 pages 35.93 Kb
Page 159
Image 159

MultiVOIP User Guide

Technical Configuration (T1/E1)

 

 

T1 Parameter Definitions (cont’d)

Field Name

Values

Description

Line Build Out

0 dB, -7.5 dB,

To reduce the crosstalk on

 

-15 dB, -22.5 dB

received signals, a transmit

 

 

attenuator can be placed in the

 

 

data path. Transmit attenuation

 

 

is selectable. Default: O dB

 

 

 

Pulse Shape

0 to 40 Meters

Refers to length of cable

Level

40 to 81 m

between MultiVOIP and

 

81 to 122 m

PBX/telco in meters. Most

 

122 to 162 m

common will be 0 to 40m.

 

162 to 200 m

 

 

 

 

Clocking

External/Internal

Set opposite to telco/PBX

 

 

setting. Example: if telco

 

 

clocking internal, set VOIP

 

 

clocking as external.

 

 

 

Line Coding

AMI / B8ZS

Match to PBX or telco.

 

 

 

PCM Law

A-Law/Mu-Law

Match to PBX or telco. “

 

 

Mu-law” is analog-to-digital

 

 

compression/expansion

 

 

standard used in North

 

 

America. “A-law” is European

 

 

standard.

 

 

 

Yellow Alarm

Bit 2 / 1111…

Depending on the Frame

Format

 

Format used, there are choices

 

 

of Yellow Alarm format, as

 

 

follows:

 

 

D4: -Bit2= 0 in every speech

 

 

channel

 

 

-FSbit of frame 12 is forced

 

 

to one.

 

 

ESF: -Bit2= 0 in every speech

 

 

channel

 

 

–1111111100000000 pattern

 

 

in data link channel.

 

 

Check with your PBX/telco

 

 

administrator for the correct

 

 

setting or use the default value

 

 

(1111 … ).

 

 

 