MultiVOIP User Guide

Technical Configuration (Analog/BRI)

 

 

 

 

 

 

 

 

 

 

 

Custom Tone-Pair Settings Definitions

 

 

 

 

 

 

 

Field Name

Values

Description

 

 

 

 

 

 

 

Cadence 1

integer time

On/off pattern of tone durations

 

 

 

value in

used to denote phone ringing,

 

 

 

milli-seconds;

phone busy, dial tone (“0”

 

 

 

zero value for

indicates continuous tone)

 

 

 

dial-tone

survivability and re-order.

 

 

 

indicates

Cadence 1 is duration of first

 

 

 

continuous tone

period of tone being “on” in the

 

 

 

 

cadence of the telephony signal

 

 

 

 

(which could be ring-tone, busy-

 

 

 

 

tone, unobtainable-tone, or dial

 

 

 

 

tone).

 

 

 

 

 

 

 

Cadence 2

duration in

Cadence 2 is duration of first

 

 

 

milliseconds

“off” period in signaling

 

 

 

 

cadence.

 

 

 

 

 

 

 

Cadence 3

duration in

Cadence 3 is duration of second

 

 

 

milliseconds

“on” period in signaling cadence.

 

 

 

 

 

 

 

Cadence 4

duration in

Cadence 4 is duration of second

 

 

 

milliseconds

“off” period in the signaling

 

 

 

 

cadence, after which the 4-part

 

 

 

 

cadence pattern of the telephony

 

 

 

 

signal repeats.

 