Technical Configuration (Analog/BRI)

MultiVOIP User Guide

 

 

E&M Interface Parameter Definitions

*Not applicable to MVP130FXS

Field Name

Values

Description

Interface

E&M

enables E&M functionality

 

 

 

Type

Types 1-5.

Refers to the type of E&M

 

 

interface being used.

 

 

 

Mode

2-wire or 4-wire

Each E&M interface type can be

 

 

either 2-wire or 4-wire audio.

 

 

 

Signal

Dial Tone or

When Dial Tone is selected, no

 

Wink

wink is required on the E lead

 

 

or M lead in the call initiation or

 

 

setup.

 

 

When Wink is selected, a wink

 

 

is required during call setup.

 

 

 

Wink Timer

integer values,

This is the length of the wink

(in ms)

in milliseconds

for wink signaling.

 

 

Applicable only when Signal

 

 

parameter is set to “Wink.”

 

 

 

Pass Through

Y/N

When enabled (“Y”), this

Enable

 

feature is used to create an open

 

 

audio path for 2- or 4-wire. The

 

 

E&M leads are passed through

 

 

the voip transparently.

 

 

Applicable only for E&M

 

 

Signaling with Dial Tone.

 

 

 

256

Page 256
Image 256
Multi-Tech Systems MVP-130/130FXS, MVP-410ST/810ST, MVP-2410/3010 manual Interface Parameter Definitions, 256