MultiVOIP User Guide

Technical Configuration (T1/E1)

 

 

E1 Parameter Definitions (cont’d)

Field Name

Values

Description

Line Build Out

0 dB, -7.5 dB,

To reduce the crosstalk on

 

-15 dB, -22.5 dB

received signals, a transmit

 

 

attenuator can be placed in the

 

 

data path. Transmit attenuation

 

 

is selectable. Default: O dB

 

 

 

Pulse Shape

0 to 40 Meters

Refers to length of cable

Level

40 to 81 m

between MultiVOIP and

 

81 to 122 m

PBX/telco in meters. Most

 

122 to 162 m

common will be 0 to 40m.

 

162 to 200 m

 

 

 

 

Clocking

External/Internal

Set opposite to telco/PBX

 

 

setting. Example: if telco

 

 

clocking internal, set VOIP

 

 

clocking as external.

 

 

 

Line Coding

AMI / HDB3

Match to PBX or telco.

 

 

 

PCM Law

A-Law/Mu-Law

Match to PBX or telco.

 

 

“A-law” is analog-to-digital

 

 

compression/expansion

 

 

standard used in Europe.

 

 

“Mu-law” is North American

 

 

standard.

 

 

 

165

Page 165
Image 165
Multi-Tech Systems MVP-410ST/810ST, MVP-130/130FXS, MVP-2410/3010 manual 165, AMI / HDB3