Image 258

Technical Configuration (Analog/BRI)

MultiVOIP User Guide

 

 

E&M Interface Parameter Definitions (cont’d)

Field Name

Values

Description

Dialing Options (cont’d)

 

 

 

 

Disconnect on

Y/N

Allows call on FXO port to be

Call Progress

 

disconnected when a PBX issues a

Tone

 

call-progress tone denoting that

 

 

the phone station on the PBX that

 

 

has been involved in the call has

 

 

been hung up.

 

 

 

Flash Hook Options fields

 

 

 

 

Generation

integer values, in

Length of flash hook that will

 

milliseconds

be generated and sent out when

 

 

the remote end initiates a flash

 

 

hook and it is regenerated

 

 

locally. Default = 600 ms.

 

 

 

Detection

for Min. and Max.,

For a received flash hook to be

Range

50 1500

regarded as such by the

 

milliseconds

MultiVOIP, its duration must

 

 

fall between the minimum and

 

 

maximum values given here.

 

 

 