Voice/Fax Parameter Definitions (cont’d)

Coder Parameters

 

Coder

Manual or

Determines whether selection of

 

Auto-

coder is manual or automatic.

 

matic

When Automatic is selected, the

 

 

local and remote voice channels will

 

 

negotiate the voice coder to be used

 

 

by selecting the highest bandwidth

 

 

coder supported by both sides

 

 

without exceeding the Max

 

 

Bandwidth setting. G.723, G.729, or

 

 

G.711 are negotiated.

 

 

 

Selected

G.711 a/u

Select from a range of coders with

Coder

law 64

specific bandwidths. The higher the

 

kbps;

bps rate, the more bandwidth is

 

G.726, @

used. The channel that you are

 

16/24/32

calling must have the same voice

 

/40 kbps;

coder selected.

 

G.727, @

 

 

nine bps

Default = G.723.1 @ 6.3 kbps, as

 

rates;

required for H.323. Here 64K of

 

G.723.1 @

digital voice are compressed to

 

5.3 kbps,

6.3K, allowing several simultaneous

 

6.3 kbps;

conversations over the same

 

G.729,

bandwidth that would otherwise

 

8kbps;

carry only one.

 

Net Coder

 

 

@

To make selections from the

 

6.4, 7.2, 8,

Selected Coder drop-down list, the

 

8.8, 9.6

Manual option must be enabled.

 

kbps

 

 

 

 

Max

11 – 128

This drop-down list enables you to

bandwidth

kbps

select the maximum bandwidth

(coder)

 

allowed for this channel. The Max

 

 

Bandwidth drop-down list is

 

 

enabled only if the Coder is set to

 

 

Automatic.

 

 

If coder selected automatically, then

 

 

enter a value for maximum

 

 

bandwidth, as directed by VOIP

 

 

administrator.

 

 

 