Multi-Tech Systems MVP-130/130FXS, MVP-410ST/810ST manual Did Interface Parameter Definitions, 259

Models: MVP-410ST/810ST MVP-130/130FXS MVP-2410/3010

1 559
Download 559 pages 35.93 Kb
Page 259
Image 259

MultiVOIP User Guide

Technical Configuration (Analog/BRI)

 

 

DID Parameters. The parameters applicable to the Direct Inward Dial (DID) telephony interface type are shown in the figure below and described in the table that follows. The DID interface allows one phone line to direct incoming calls to any one of several extensions without a switchboard operator. Of course, one DID line can handle only one call at a time. The parameters described here pertain to the customer- premises side of the DID connection (DID-DPO, dial-pulse originating); the network side of the DID connection (DID-DPT, dial-pulse terminating) is not supported.

DID Interface Parameter Definitions

*Not applicable to MVP130FXS

Field Name

Values

Description

Interface

DID-DPO

Enables the customer-premises

 

 

side of DID functionality

 

 

 

DID Options

MultiVOIP’s use of DID applies

 

 

only for incoming DID calls.

 

 

The Start Mode used by the

 

 

MultiVOIP must match that

 

 

used by the originating

 

 

telephony equipment, else DID

 

 

calls cannot be completed.

 

 

 

Start Modes

Immediate Start,

For Immediate Start, the voip

 

Wink Start,

detects the off-hook condition

 

Delay Dial

initiated by the telco central-

 

 

office call and becomes ready to

 

 

receive dial digits immediately.

 

 

 

259

Page 259
Image 259
Multi-Tech Systems MVP-130/130FXS, MVP-410ST/810ST, MVP-2410/3010 manual Did Interface Parameter Definitions, 259