MultiVOIP User Guide

 

Technical Configuration (T1/E1)

 

 

 

 

 

 

 

 

 

 

 

Custom Tone-Pair Settings Definitions

 

 

 

 

 

 

 

 

Field Name

Values

 

Description

 

 

 

 

 

 

 

 

Cadence 1

integer time

 

On/off pattern of tone durations

 

 

 

value in

 

used to denote phone ringing,

 

 

 

milli-seconds;

 

phone busy, connection

 

 

 

zero value for

 

unobtainable tone (fast busy),

 

 

 

dial-tone

 

dial tone (which is continuous

 

 

 

indicates

 

and described as “0“) & re-

 

 

 

continuous tone

 

order tone. Cadence 1 is

 

 

 

 

 

duration of first period of tone

 

 

 

 

 

being “on” in the cadence of the

 

 

 

 

 

telephony signal (which could be

 

 

 

 

 

ring-tone, busy-tone,

 

 

 

 

 

unobtainable tone, dial tone, or

 

 

 

 

 

re-order tone).

 

 

 

 

 

 

 

 

Cadence 2

duration in

 

Cadence 2 is duration of first

 

 

 

milliseconds

 

“off” period in signaling

 

 

 

 

 

cadence.

 

 

 

 

 

 

 

 

Cadence 3

duration in

 

Cadence 3 is duration of second

 

 

 

milliseconds

 

“on” period in signaling cadence.

 

 

 

 

 

 

 

 

Cadence 4

duration in

 

Cadence 4 is duration of second

 

 

 

milliseconds

 

“off” period in the signaling

 

 

 

 

 

cadence, after which the 4-part

 

 

 

 

 

cadence pattern of the telephony

 

 

 

 

 

signal repeats.

 

177