FXO Interface: Parameter Definitions (cont’d)

 

 

 

 

 

 

 

 

 

Field Name

Values

Description

 

 

 

 

 

 

 

Dialing Options (cont’d)

 

 

 

 

 

 

 

 

Inter Digit

50 to 20,000

The length of time between the

 

 

Regeneration

milliseconds

outputting of DTMF digits.

 

 

Time

 

Default = 100 ms.

 

 

 

 

 

 

 

FXO Disconnect On

There are three possible criteria

 

 

 

 

for disconnection under FXO:

 

 

 

 

current loss, tone detection, and

 

 

 

 

silence detection.

 

 

 

 

Disconnection can be triggered

 

 

 

 

by more than one of the three

 

 

 

 

criteria.

 

 

 

 

 

 

 

Current Loss

Y/N

Disconnection to be triggered

 

 

 

 

by loss of current. That is,

 

 

 

 

when Current Loss is enabled

 

 

 

 

(“Y”), the MultiVOIP will hang

 

 

 

 

up the call when it detects a loss

 

 

 

 

of current initiated by the

 

 

 

 

attached device.

 

 

 

 

 

 

 

Current Loss

integer values

The minimum time required for

 

 

Detect Timer

(in milliseconds )

detecting the current loss signal

 

 

 

 

on the FXO interface. In other

 

 

 

 

words, this is the minimum

 

 

 

 

length of time the current must

 

 

 

 

be absent to validate ‘current

 

 

 

 

loss’ as a disconnection

 

 

 

 

criterion. Default = 500 ms.

 

 

 

 

 

 

 

Tone Detection

Y/N

Disconnection to be triggered

 

 

 

 

by a tone sequence.

 

 

 

 

 

 