Installing the AN/DC
Space Requirements
The installation site must provide a certain amount of free space around the AN/DC to dissipate heat. Install the AN/DC in a space that meets the following specifications:
•Width: 19.5 in. (49.6 cm)
•Minimum depth: 15.5 in. (39.3 cm)
•Depth for servicing: 24.5 in. (62.2 cm)
Electrical Requirements
The installation site must provide an isolated power source that meets these electrical specifications:
•Input voltage of
•1.5 amperes (A) input current under full load at
•Reinforced insulation from the main AC power
We recommend the use of #16 AWG cables between the AN/DC and the power source to minimize voltage drop. When measuring the cable run, be certain to include both the input and return cables.
Environmental Requirements
The AN/DC installation site must meet the following specifications:
•Altitude: 0 to 8,000 ft (0 to 2,438.4 m)
•Humidity: 10% to 90%, noncondensing
•Temperature: 32 °F to 104°F (0°C to 40°C) stable