Nortel Networks AN/DC manual Installing the ANH-8/DC in a Rack

Models: AN/DC

1 150
Download 150 pages 33.07 Kb
Page 49
Image 49

Installing the ANH-8/DC

Installing the ANH-8/DC in a Rack

For this procedure, you need

Four #10 cagenut screws and washers (shipped with the ANH-8/DC)

Two flange brackets and eight #6 flathead screws (shipped with the ANH-8/DC)

A Phillips screwdriver

An electronic enclosure rack

Note: If the rack’s rail does not have threaded holes, you must supply and attach four cagenuts.

To install the ANH-8/DC in a rack:

1.Attach a flange bracket to both sides of the ANH-8/DC. On each side of the chassis:

a.Align the holes in the longer end of the bracket with the mounting holes near the front of the ANH-8/DC (Figure 2-3).

b.Insert a #6 flathead screw through each hole and into the ANH-8/DC.

c.Tighten the four screws with a Phillips screwdriver.

312410-A Rev 00

2-7