[9] SELF DIAGNOSTICS
1. Summary/purpose
This model has the self diag function for the following purposes:
1)When a trouble occurs in the machine, the machine detects the trouble and displays the trouble content on the copy quantity dis- play to alert the customer and the serviceman.
2)When any abnormality is detected, the power supply line is cut off immediately for safety and to protect the machine from damage.
2. Operation
The self diag content is displayed in the following procedure.
A trouble occurs
The abnormalality is detected by sensors and detectors
The main trouble code is displayed on the copy quantity display
YES |
Is there |
sub code? |
NO |
Check the trouble position (Use the suitable simulation)
Press the print key
The sub trouble code
is displayed on the copy quantity display
Repair
Turn off/on the power or cancel the self diag with simulation 14 or 16
3. Clearing the self diag display
After repairing the trouble section, clear the self diag display accord- ing to the table below:
Clearing the self diag display
Self diag display | Display clearing procedure | |
|
| |
L1, L3, L4, L5, L8 | Turn off/on the power. | |
|
| |
H3, H4 | Execute simulation 14. | |
|
| |
U2 | Execute simulation 16. | |
|
| |
CH, PC | When the trouble is cancelled,, the display is | |
cleared. | ||
| ||
|
|
9 – 1