1Take out the process unit as shown above,
<Note> If the unit is removed by holding the toner transport pipe, toner is spilled. Avoid this.
2Remove the bottle cover. (2 screws)
3Rotate waste toner bearing 1 A 90 degrees counterclockwise. Hole the base of toner transport pipe B and pull it out. (At this time, toner may be spilled. Put a sheet under the pipe.
4While pushing waste toner bottle in the direction of A and lift it and remove.
A
(Note for assembly/maintenance)
1As shown in the figure below, attach so that two projections of gear 19T g are on the rear frame side (on the screws supporting plate f side).
g
A
f
2 Replace the waste toner bottle when waste toner full is detected or at 50K maintenance. At this time, clean and remove the waste toner from waste toner pipe A.
B
A
6 – 18