Sharp SF-1120, SF-1020 service manual Optical system, Adjustment items

Models: SF-1120 SF-1020

1 140
Download 140 pages 48.95 Kb
Page 76
Image 76

(5)Measure the distance from the marking position to the bottom

(A)of the developing unit and check that the distance is 17.6mm. If the distance is not as specified above, loosen the MG adjustment plate fixing screw, move the adjustment plate in the arrow directions and perform procedures (3) to (5) again.

17.6mm

A

(6)After completion of adjustment, tighten the MG adjustment plate fixing screw. When tightening, check that the bias ter- minal is as shown below. After tightening the screw, apply screw lock to it.

MG adjustment plate

MG adjustment plate fixing screw Bias terminal

MG adjustment plate

2. Optical system

2-1. Adjustment items

1.Lens reference position adjustment

2.No. 4/5 mirror reference position adjustment

3.Vertical copy magnification ratio adjustment

4.Resolution adjustment

5.Horizontal copy magnification ratio adjustment

6.Comparison table of lens values and simulation input values

7.Vertical skew adjustment

8.Horizontal skew adjustment

9.Center shift adjustment

10.Exposure balance adjustment

11.Copy lead edge adjustment

7 – 2

Page 76
Image 76
Sharp SF-1120, SF-1020 service manual Optical system, Adjustment items