Epson 7000 service manual CR Timing Belt Tension Adjustment, PF Timing Belt Tension Adjustment

Models: 7000

1 231
Download 231 pages 2.07 Kb
Page 198
Image 198

EPSON Stylus Pro 7000

Revision B

CR TIMING BELT TENSION ADJUSTMENT

This adjustment is necessary for service operations that require you to remove/loosen the CR Motor or CR Steel Belt. When replacing or re-installing the CR Steel Belt, you need to confirm the tension of the CR Steel Belt. Tighten or loosen the screws on the Driven Pulley to increase or decrease the tension.

Standard:

8000g ± 10% (at the point where the CR Steel Belt

 

contacts the CR Rail)

CR

CR

Timing

Belt

Tension

 

Screw

CR Tension Bracket

Hook the tension gauge here and

 

pull directly to the right, parallel to

 

the timing belt. Fix the screw at a

 

tension of 8000g ± 10%.

Figure 5-44. CR Timing Belt Tension Adjustment

PF TIMING BELT TENSION ADJUSTMENT

This adjustment is necessary for service operations that require you to remove/loosen the PF Motor or PF Belt. When replacing or re-installing the PF Belt, you need to confirm the tension of the PF Belt.

Standard:

2,200g ± 10%

1) Insert the Tension Gauge hook in the PF Motor holder hole

2) Pull directly away from the PF Belt until the tension gauge reads 2200g ± 10%

3) Secure the screws

Figure 5-45. PF Belt Tension

Adjustment

Mechanism Adjustment

198

Page 198
Image 198
Epson 7000 CR Timing Belt Tension Adjustment, PF Timing Belt Tension Adjustment, CR Tension Bracket, Secure the screws