Epson 7000 Test Menu Items, Do not attempt the D/A Revision or Head Signal test. These

Models: 7000

1 231
Download 231 pages 2.07 Kb
Page 166
Image 166

EPSON Stylus Pro 7000

Revision B

5.4.1 Test Menu

The Test menu tests or checks the operation of the control circuit board.

Table 5-5. Test Menu Items

The menu items and their order in the menu are shown below.

[Pause] returns you to previous menu

[SelecType][Enter]

Test Item

 

Description

 

 

 

 

Program

Version

Backup parameters

DIP-SW

 

 

Board Rev.

 

 

 

 

Panel buttons

Control Panel

LCD panel display

 

LED indicators

 

HP, Cover Open, Paper Set Lever, P_FRONT, P_REAR,

Sensors

P_EDGE, P_THICK, PG, Thermistor, I/C Holder Levers,

 

Ink ID, I/C, and Ink Low

 

 

Encoder

CR Motor, PF Motor

 

 

Fan

On/Off confirmation

 

 

 

Elec.

Maintenance Record

Fatal Error Record

 

D/A Revision

Factory use for Head voltage correction - do not

attempt

 

 

 

Head Signal

Factory use for Head pulse check - do not attempt

 

 

 

Do not attempt the D/A Revision or Head Signal test. These

C A U T I O N

tests are only performed with special equipment during the manufacturing process. Any changes will mar print quality

Test: Version

Test: Panel

Test: Sensor

Test: Encoder

Test: Fan

Test: Elec.

Test: D/A Revision

Test: Head Signal

[Item]

Other

menus

[Pause]

Figure 5-3. Test Menu

Adjustment

Self-Diagnostic Mode Menus

166

Page 166
Image 166
Epson 7000 Test Menu Items, Do not attempt the D/A Revision or Head Signal test. These, Test Item Description