Epson 7000 service manual PEdge, PFront, and PRear Sensor Adjustment, Sensor Volume Adjustment

Models: 7000

1 231
Download 231 pages 2.07 Kb
Page 170
Image 170

EPSON Stylus Pro 7000

Revision B

†P_EDGE Sensor adjustment

1.If necessary, remove the access cover on the rear cover and enter the "Test Menu" in the self-diagnostic mode. Select "Sensors" check mode

2.Select “Sen:EdgeAD” from the sensor menu.

3.Push the cutter cap to release the carriage lock and move the carriage about 20cm (roughly 9 inches) to the left. Make sure the panel shows 018 or less.

4.Push the Paper Set Lever back and load a sheet of A3-size (portrait) normal copy paper using the guide on the right side of the roll paper cover. Pull the Paper Set Lever forward to lock the paper in place.

5.Open the front cover, and press down the cutter and move the carriage over the paper. Close the front cover.

6.The LCD will display “Sen:EdgeAD ttt vvv”

ttt= threshold; 0E0~0E8; ideal = 0E0 vvv = volume; 040 or more

Make sure that the vvv signal level indicated on the LCD is over 040 and the ttt signal level indicated on the LCD is between 0E0~0E8.

Table 5-6. P_Edge, P_Front, and P_Rear Sensor Adjustment

Sensor

ttt Parameter

vvv Parameter

(no paper)

 

 

 

 

 

P_Edge

040 or higher

0E0~0E8

 

 

 

P_Front & P_Rear

040 or higher

095 or less

 

 

 

Table 5-7. Sensor Volume Adjustment

Sensor

Rough Volume

Precision Volume

Adjustment

Adjustment

 

 

 

 

P_Edge

VR1

VR5

 

 

 

P_Front

VR2

VR6

 

 

 

P_Rear

VR3

VR4

 

 

 

7.Through the access cover, adjust the volume on VR1 (rough adjustment) and VR5 (precise adjustment) so that vvv = 0E0~0E8. However, if ttt = less than 040, adjust vvv to 0E8.

Figure 5-7. VR1~VR6 Positions Viewed Through Access Cover

NOTE: If the signal level cannot be adjusted properly, check the position of the sensor and if this does not correct the signal level, replace the sensor.

8.Open the front cover, and move the carriage back to the home position.

9.Release the Paper Set Lever, remove the paper, and return the Lever to the Set position. Then press the SelecType button and proceed to the next sensor adjustment (if necessary).

Adjustment

Self-Diagnostic Mode Menus

170

Page 170
Image 170
Epson 7000 service manual PEdge, PFront, and PRear Sensor Adjustment, Sensor Volume Adjustment, † Pedge Sensor adjustment