4.2.3.19 Removing the HEAD_SLIDE Sensor Assembly

1.Remove the R Side Cover as described in “R Side Cover Removal” on page 114.

2.Remove the Rear Cover as described in “Rear Cover Removal” on page 118.

3.Disconnect the harness for the HEAD_SLIDE Sensor Assembly from its connector on the main board and take the harness out from the hole in the R Side Frame.

Clamp 2/4

Clamp 1/4

4.Push the carriage lock using your finger to unlock the carriage and move the carriage from the home position to the left.

5.Remove the one (CP(W) M3x6) screw securing the HEAD_SLIDE Sensor Assembly and remove the HEAD_SLIDE Sensor Assembly.

6.Release the harness for the HEAD_SLIDE Sensor Assembly from the four cable clamps on the Maintenance Assembly and CR Rail Assembly.

Clamp (on

Sensor

the CR rail)

Harness

 

Clamp (on the

Maintenance

Base)

HEAD_SLIDE

SensorScrew

Assembly(M3x6)

Figure 4-76. Removing the HEAD_SLIDE Sensor Assembly