EPSON Stylus Pro 7000

Revision B

2.4.1 Power Supply Board Summary

Depending on the printer model, either 100V AC or 220V AC is supplied to the printer when the printer is plugged into an live outlet.

When plugged into a live power outlet, the power supply board is working.

Even after pressing the power switch to turn off the printer,

C A U T I O N

power is supplied to and from the power supply board. During the power-down sequence, power is supplied to the CR motor to move the printheads to the capped position to prevent ink from clogging the nozzles.

Always turn off the printer using the power switch - do not remove the power cable from the wall outlet while the printer is on or while internal parts are moving.

To prevent over-current damage to the PS board, the following fuser is supplied on the PS board.

100V AC ± 10% = 125V AC/6.3A

The C299MAIN board has three control signals, described in detail in the table below.

Table 2-7. PS Board Signal Summary

Signal Name

 

Condition

 

Function

 

 

 

 

 

+28V/+42V

 

During operation

 

The On/Off status is controlled from the

 

 

C299MAIN board.

 

 

 

REM_ON

 

 

 

 

 

 

 

When this terminal is released (=L), the

(MAIN ->PS)

 

Printer off

 

 

 

 

28VDC and 42VDC lines drop to 0VDC.

 

 

 

 

 

 

 

 

 

 

 

 

 

When turned on, the PS board is

 

 

During operation

 

enabled and all lines go active. After

 

 

(= H)

 

that, the “H” signal is sent to the

 

 

 

 

C299MAIN board.

AC_OFF

 

 

 

 

 

 

 

When turned off, the PS board is still

(MAIN<-PS)

 

 

 

 

 

 

enabled, but all lines go inactive. After

 

 

 

 

 

 

Printer off

 

that the “L” signal is sent to the

 

 

(= L)

 

C299MAIN board (this also occurs if the

 

 

 

 

incoming power drops below the rated

 

 

 

 

voltage).

 

 

 

 

 

 

 

Turning on

 

This terminal closes and the PS board is

POWER_SW

 

 

activated.

 

 

 

 

 

 

 

(Panel/MAIN ->

 

 

 

 

 

 

 

This terminal releases and remains

PS)

 

 

 

 

Turning off

 

active anywhere from10+ seconds to

 

 

 

 

 

 

 

several minutes.

 

 

 

 

 

Operating Principles

Summary of Control Circuit Operations

78

Page 78
Image 78
Epson 7000 service manual Power Supply Board Summary, PS Board Signal Summary, Signal Name Condition Function