COVER OPEN SENSOR ASSEMBLY

When removing/replacing the Cover Assembly or the Front Cover, verify the sensor operation using the Self-Diagnostic mode as described below.

1.Press the following buttons and turn on the printer to enter the Self- Diagnostics mode.

[Paper Feed ↓] + [Cut/Eject] + [Cleaning]

2.Press the SelecType or Item button until "Check: Test" appears in the LCD, then press the Enter button to select the Test menu.

3.Press the SelecType or Item button until "Test: Sensor" appears in the LCD, then press the Enter button to select the Test Item menu.

4.Press the SelecType or Item button until "Sen: Cover xxxx" appears.

5.Open and close the Front Cover, checking the LCD to make sure the message changes depending on the Front Cover position.

Table 5-17. Cover Sensor Assembly Check

Front Cover

 

LCD Message

 

 

 

 

Open

 

Sen: Cover

Open

 

 

 

 

Closed

 

Sen: Cover

Close

 

 

 

 

6.If the correct message does not appear or any other message appears, verify the Cover Sensor is installed correctly and check the operation again. If necessary, loosen the screw securing the sensor and adjust the position up or down until the cover open sensor operates correctly. Then tighten the screw.