EPSON Stylus Pro 7000

Revision B

4.2.3.14 Removing the Pump Motor Assembly

1.Remove the Maintenance Assembly as described in “Removing the Maintenance Assembly” on page 143.

2.Release the harness for the Pump Motor Assembly from the cable clamp.

3.Remove the three (CP(W) M3x8) screws securing the Pump Motor Assembly to the Maintenance Base Assembly and remove the Pump Motor Assembly.

Pump Motor

Assembly

Clamp

Screws (M3x8)

Figure 4-69. Removing the Pump Motor Assembly

Disassembly & Assembly

Disassembly Flow

146

Page 146
Image 146
Epson 7000 service manual Removing the Pump Motor Assembly, Pump Motor Assembly Clamp Screws M3x8