4.2.3.16 Removing the Pump Assembly

1.Remove the Maintenance Assembly as described in “Removing the Maintenance Assembly” on page 143.

2.Remove the Cap Assembly as described in “Removing the Cap Assembly” on page 147.

3.Remove the two (CUPS M3x6) screws securing the pump reduction gear bracket and remove the pump reduction gear bracket and pump gear.

NOTE: When mounting the pump reduction gear, make sure the reduction gear mesh with the corresponding gear.

4.Remove the one (CUPS M3x6) screw securing the Pump Assembly and remove the Pump Assembly.

Pump

Screw (M3x6)

Pump Gear

Pump

Reduction Gear

Bracket

Screws (M3x6)

Figure 4-73. Removing the Pump Assembly

4.2.3.17 Removing the Cleaner Head

1.Remove the Maintenance Assembly as described in “Removing the Maintenance Assembly” on page 143.

2.Remove the Cap Assembly as described in “Removing the Cap Assembly” on page 147.

3.Using tweezers, release the joint for the concave part of the Cleaner Head and the convex part of the Cleaner Head support part in the Pump Assy. Then remove the Cleaner Head by pulling it upward.

NOTE: Set the Cleaner Head in the correct direction, and do not touch the Cleaner Head with your bare hands.

Cleaner Head (Front part is rubber)

Tweezers

Pump

Assembly

Figure 4-74. Removing the Cleaner Head