1.10 Jumper Settings

The factory default settings for jumper and DIP switch on the Main Board (C299MAIN) are as follows.

Table 1-41. Jumper Settings

Type

 

Number

 

Setting

 

 

 

 

 

Jumper

 

JP1

 

Jumpered

 

 

 

 

 

Jumper

 

JP2

 

Jumpered

 

 

 

 

 

DIP-SW

 

SWD1 “1” (1-4)

 

OFF (Open)

 

 

 

 

 

DIP-SW

 

SWD1 “2” (2-3)

 

OFF (Open)

 

 

 

 

 

1.11 Initialization

There are three ways to initialize the EPSON Stylus Pro 7000:

†Hardware initialization:

When the power is turned on or a cold-reset command is sent to the printer (remote RS command), the printer does the following:

„Initializes the printer mechanism

„Clears the input data buffer

„Clears the print buffer

„Restores the default values

†Software initialization:

When the printer receives an ESC @ command, it does the following:

„Clears the print buffer

„Restores the default values

†Control panel (operator) initialization:

When the Pause button is pressed for more than two seconds or the printer receives an -INIT signal (negative pulse) from the parallel interface, the printer:

„If a single sheet is loaded, the printer ejects the sheet. If roll paper is loaded and Auto Cut is selected, the printer cuts the printed area off and reverse feeds the paper. If roll paper is loaded and Cutter Off is selected, the printer reverse feeds the paper.

„Caps the printheads

„Clears the input data buffer

„Clears the print buffer

„Resets the default values

The default values are shown below.

Page Position:

Current paper position as page-start position

Line feed:

1/6”

Right margin:

237th character

Left margin:

1st character

Character pitch:

10 CPI

Print mode:

Text mode (non-raster graphics mode)