Main code | Sub code |
|
|
|
|
|
| Content | |
|
|
|
|
|
|
|
|
| |
51 | 02 | Resist amount adjustment |
|
| |||||
|
| Used to set the warp amount of paper in the resist section. | |||||||
|
| When this simulation is executed, | |||||||
|
| copy quantity display. |
|
| |||||
|
| After completion of | |||||||
|
| Since there are two or more display items, the third digit is used to make distinction between the light reception | |||||||
|
| level and the original judgment level, and the lower two digits are used to display the data. | |||||||
|
| The display is selected by the magnification ratio key. | |||||||
|
|
|
|
|
|
|
|
| |
|
|
| Copy quantity display |
| Display data |
| |||
|
|
|
|
|
|
|
|
| |
|
|
| 3rd digit |
| 2nd, 1st digits |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| A |
| 1 ∼ 99 |
| Tray resist amount |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| b |
|
|
| Manual feed resist amount |
| |
|
|
|
|
|
|
|
|
| ← |
|
|
| C |
|
|
| ADU paper feed resist amount | ||
|
|
|
|
|
|
|
|
|
|
|
| Set range: 1 ∼ 99 |
|
|
|
|
| ||
|
| After completion of setting, press the CA key to cancel the adjustment mode. | |||||||
|
|
|
|
|
| ||||
52 | 01 | ADU alignment plate home position adjustment | |||||||
|
| Used to adjust the alignment plate home position by entering figures. | |||||||
|
| When this simulation is executed, the currently set adjustment value is displayed on the copy quantity display. | |||||||
|
| The setting range is 1 ∼ 8 ∼ 30. |
|
| |||||
|
| The smaller the set value is, the wider the alignment plate home position is. | |||||||
|
|
|
|
|
| ||||
| 02 | ADU rear edge plate home position adjustment | |||||||
|
| Used to adjust the rear edge plate home position by entering figures. | |||||||
|
| When this simulation is executed, the currently set adjustment value is displayed on the copy quantity display. | |||||||
|
| The set range is 1 ∼ 8 ∼ 30. |
|
| |||||
|
| The smaller the set value is, the wider the rear edge plate home position is. | |||||||
|
|
|
|
|
| ||||
| 03 | ADU transport motor adjustment | |||||||
|
| Used to vary the transport motor speed in the case of ADU paper | |||||||
|
| entry. |
|
|
|
|
| ||
|
| When this simulation is executed, the currently set adjustment value is displayed on the copy quantity display. | |||||||
|
| Enter the set value and press the PRINT button to store it. | |||||||
|
|
|
|
|
|
|
| ||
|
|
| Set value |
| Transport speed |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 150 mm/s |
|
|
|
|
|
| 50 |
|
| 130 mm/s |
|
|
|
|
|
|
|
|
| 100 mm/s |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| |||||
53 | 01 | (R)ADF (single) stop position setting |
|
| |||||
|
| Used to set the original stop position in ADF (single) transport. | |||||||
|
| When this simulation is executed, the currently set stop position data is displayed on the copy quantity display. | |||||||
|
| Enter the set value and press the PRINT button to store it. | |||||||
|
| Setting range: 0 ∼ 15 |
|
| |||||
|
|
|
|
| |||||
| 02 | (R)ADF (duplex) stop position setting |
|
| |||||
|
| Used to set the original stop position in ADF (duplex) transport. | |||||||
|
| When this simulation is executed, the currently set stop position data is displayed on the copy quantity display. | |||||||
|
| Enter the set value and press the PRINT button to store it. | |||||||
|
| Setting range: 0 ∼ 15 |
|
| |||||
|
|
|
|
| |||||
| 04 | ADF resist sensor adjustment |
|
| |||||
|
| Used to adjust the ADF resist sensor original judgement level. | |||||||
|
| When this simulation is executed, the resist sensor original judgement level is adjusted. After completion of | |||||||
|
| adjustment, the original judgement level is displayed on the copy quantity display. | |||||||
|
| Display range: 0 ∼ FFh (hexadecimal) |
|
| |||||
|
|
| |||||||
| 05 | ADF paper exit reverse sensor adjustment | |||||||
|
| Used to adjust the ADF paper exit reverse sensor original judgement level. | |||||||
|
| When this simulation is executed, the paper exit reverse sensor original judgement level is adjusted. After | |||||||
|
| completion of adjustment, the original judgement level is displayed on the copy quantity display. | |||||||
|
| Display range: 0 ∼ FFh (hexadecimal) |
|
| |||||
|
|
|
|
|
|
|
|
|
|
8 – 19