Main code | Sub code |
|
|
|
|
| Content |
| |
|
|
|
|
|
|
|
|
|
|
24 | 01 | Jam memory/total jam counter clear |
|
|
| ||||
|
| The cause (position) of a jam which occurred during copying and the jam total counter are cleared, and the jam | |||||||
|
| total counter value is displayed on the copy quantity display. (“000” is displayed because the counter is cleared.) | |||||||
|
|
|
|
|
|
|
|
|
|
| 02 | Trouble memory clear |
|
|
| ||||
|
| The main code and the sub code of a trouble is cleared. |
| ||||||
|
| (“000” is displayed because the memory is cleared.) |
| ||||||
|
|
|
|
|
|
|
|
|
|
| 03 | ADU counter clear |
|
|
| ||||
|
| Used to clear the ADU counter and to display the ADU counter value on the copy quantity display. | |||||||
|
| (“000” is displayed because the counter is cleared.) |
| ||||||
|
|
|
|
|
|
|
|
|
|
| 04 | ADF counter clear |
|
|
|
|
| ||
|
| Used to clear the ADF counter and to display the ADF counter value on the copy quantity display. | |||||||
|
| (“000” is cleared because the counter is cleared.) |
| ||||||
|
|
|
|
|
|
|
|
|
|
| 05 | Staple counter clear |
|
|
|
|
| ||
|
| Used to clear the staple counter and to display the staple counter value on the copy quantity display. | |||||||
|
| (“000” is displayed because the counter is cleared.) |
| ||||||
|
|
|
|
|
|
|
|
|
|
25 | 01 | Drive system check |
|
|
|
|
| ||
|
| Used to turn on the main motor, the developing bias, and the discharge lamp for 3 min. | |||||||
|
| The input value of the toner density is displayed on the second digit of the copy quantity display during the main | |||||||
|
| motor is rotating. The third digit indicates the color of developer. |
| ||||||
|
|
|
|
|
|
|
|
| |
|
|
| Copy quantity display | Color of developer |
|
| |||
|
|
|
|
|
|
|
| ||
|
|
| Third digit | Second, first digit |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| A |
|
| Black |
|
| |
|
|
|
|
| 1 ∼ 99 |
|
|
|
|
|
|
| b |
| Red |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| C |
|
| Blue |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 02 | Automatic developer adjustment |
|
|
| ||||
|
| Same as SIM | |||||||
|
| value after 3 min from starting the main motor rotation. |
| ||||||
|
| The display on the copy quantity display is same as SIM |
| ||||||
|
|
|
|
|
|
|
|
|
|
26 | 01 | Option setting |
|
|
|
|
| ||
|
| Set to “1” only when the option desk is CM16 |
| ||||||
|
| The initial setting is “0.” |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| 05 | Count mode setting |
|
|
|
|
| ||
|
| Used to set the count mode of the total counter, the developer counter (mini maintenance counter for Japan), and | |||||||
|
| the maintenance counter in A3/WLT copy. |
|
|
| ||||
|
| When this simulation is executed, the currently set count mode is displayed on the copy quantity display. | |||||||
|
| Enter the set value and press the PRINT button to store it. |
| ||||||
|
|
|
|
|
|
|
| ||
|
|
| Set value |
| Total/Developer counter | Maintenance count |
| ||
|
|
|
|
|
|
| ← Initial value | ||
|
|
| 0 |
| Double count | Double count | |||
|
|
|
|
|
|
|
| ||
|
|
| 1 |
| Single count | Double count |
| ||
|
|
|
|
|
|
|
| ||
|
|
| 2 |
| Double count | Single count |
| ||
|
|
|
|
|
|
|
| ||
|
|
| 3 |
| Single count | Single count |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8 – 9