2

3

4

3Fix the mirror base wire to the pulley with the mirror base wire fixing screw.

4Return the 9th winding tip of the mirror base wire to the original position. (Perform the same procedure for the front frame side and the rear frame side.)

(Note) After replacing the mirror base drive wire, perform the vertical skew adjustment, the focus adjustment, and the horizontal skew adjustment.

3)No. 2/3 mirror unit (mirror base B) installation (Mirror base B positioning)

This is to adjust the parallelism of mirror base B and the drum surface and the original surface.

This adjustment must be performed in the following cases:

When the mirror base drive wire is replaced.

When mirror base A or mirror base B is replaced.

1Manually turn the mirror base drive pulley to bring the mirror base B in contact with the mirror base positioning plate. If the front side and the rear side of the mirror base B make contact with the mirror base positioning plate simultaneously, the parallelism of the mirror base B is proper, and there is no further adjustment.

Mirror base positioning plate

No.2/3 mirror unit

2If the parallelism of the mirror base B is improper as shown in the figure below (one side of the mirror base B is in contact with the positioning plate and the other side is not in contact), perform the following procedure.

3Loosen the mirror base drive pulley fixing screw on the side where the mirror base B is not in contact with the positioning plate.

4Manually rotate the mirror base drive pulley on the side where the mirror base B is not in contact with the positioning plate to bring the mirror base B into contact with the positioning plate.

3

5Tighten the mirror base drive pulley fixing screw.

6Manually rotate the mirror base drive pulley to separate the mirror base B from the mirror base positioning plate once, then bring it into contact with the positioning plate.

Check that the front side and the rear side of the mirror base B make contact with the positioning plate simultaneously.

7If the condition of 6 is not satisfied, repeat procedures 3 through 6 until the condition is satisfied.

6 – 10

Page 57
Image 57
Sharp SF-1020, SF-1120 service manual