(Example) When La=12mm and Lb=9mm, shift the paper exit side mirror base B rail upward by 1.5mm.

When Lc > Ld, shift the mirror base B rail downward by half of the difference of Lc – Ld.

When Lc < Ld, shift the mirror base B rail upward by half of the difference of Lc – Ld.

(When moving the mirror base rail, hold the mirror base rail handle.)

2Adjust according to procedure (1) so that La=Lb and Lc=Ld are satisfied.

3After completion of the adjustment, turn the mirror base drive pulley manually to full scan mirror base A and mirror base B, and check that the mirror bases are not brought into contact with each other.

(Note) When the mirror bases are moved extremely, they may be brought into contact. Carefully avoid it.

I. Center shift adjustment

a. This adjustment must be performed in the following cases:

The copy (100%) center is shifted from the original center

 

more than 2mm.

When any part of the lens rail or the lens unit is replaced.

(5)Remove the document reference plate and the right upper side cabinet, and remove the document table glass.

Document reference plate

Document table glass

Right upper side cabinet

(6)Loosen the three fixing screws of the optical system unit and slide the optical system unit to adjust the center position.

<Adjustment procedure>

(1)make a test chart for center position adjustment. (Refer to the figure below.)

Draw a line at the center

Copy paper (A4 or 11" x 8½")

Paper transport direction

(2)Set the test chart for the center position adjustment to the

document reference line, and make a normal (100%) copy with an A4 or 11" × 812" paper.

(3)Check that the copied image line is at the center of the copy paper.

B

Optical system unit

Loosen the

screwsA (3pcs.)

Lens bearing side

Original

center

(Original)

Copy

paper

center

2mm

or less (Copy 1)

Move lens is the A direction

Lens

Copy

body

paper

side

center

2mm

(Copy 2)

or less

Move lens is the B direction

(Copy A)

(Copy B)

2.0mm or less

Shift

2.0mm or less

Shift

(Paper feed direction)

Copy image

Copy paper fold

Copy paper fold

Copy image

(7)After adjustment, set the removed parts in the reversed se-

quence. make a copy of the test chart to check that the center shift is within the specified range (0 ±2.0mm). If the center shift

is within the specified range, the adjustment is completed. If not, repeat procedures (2) – (7) until it is within the specified range.

J. Exposure balance adjustment

a. This adjustment is to provide uniform exposure, and must be

performed in the following cases:

When the reflector is replaced.

When the copy lamp is replaced.

(4)If the error of the copy image line is within the specified range (0±2.0mm), the adjustment is not required. If not, perform the following procedures.

When the exposure adjustment plate is replaced.

<Adjustment procedure>

(1)Set a half tone paper on the original table and make a half tone copy at 100%.

(2)If the exposure of the half tone copy is uniform, the adjustment is not required. If it is varied as shown below, perform the following procedures.

Exposure

insufficient

Paper discharge direction

Half-tone copy

7 – 12

Page 86
Image 86
Sharp SF-1120, SF-1020 service manual Center shift adjustment, Exposure balance adjustment