2-2. Note for adjustments

1.Only the exposure balance adjustment, the blank lamp adjust- ment, and the copy lead edge adjustment can be performed individually.

For the other adjustments, follow the flowchart below.

1. Mechanical reference position adjustment (without copying)

A. No. 2/3 mirror unit parallelism adjustment

Vertical skew copy adjustment --- Manual adjustment

B. Check the following preset values according to the lens focus rank.

Lens reference position adjustment --- SIM 48-01

No. 4/5 mirror reference position adjustment --- Manual adjustment

2. Adjustment while copying

 

 

 

Image distortion

1. Image distortion,

NO

Vertical skew copy adjustment

Horizontal skew copy adjustment

center shift check

 

 

Center shift:

 

 

 

 

 

 

Lens center shift adjustment

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.Normal (x 1.00), zooming (x 2.00) resolution (focus)

check

YES

 

Resolution (focus) adjustment

NO

Normal: Adjust with the No. 4/5

mirror adjustment screw.

 

 

Zooming: Adjust with the zooming

 

cam.

 

 

 

 

 

 

3. Normal copy

 

Copy magnification ratio adjustment

NO

Vertical copy magnification ratio

magnification ratio

adjustment

(vertical, horizontal)

 

 

Horizontal copy magnification

check

 

 

ratio adjustment

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Exposure balance,

Exposure balance adjustment Blank lamp position adjustment

blank lamp position, lead edge variation check

NO

Copy lead edge adjustment (Including the void area adjustment.)

YES

END