1.Only the exposure balance adjustment, the blank lamp adjust- ment, and the copy lead edge adjustment can be performed individually.
For the other adjustments, follow the flowchart below.
1. Mechanical reference position adjustment (without copying)
A. No. 2/3 mirror unit parallelism adjustment
Vertical skew copy adjustment
B. Check the following preset values according to the lens focus rank.
Lens reference position adjustment
No. 4/5 mirror reference position adjustment
2. Adjustment while copying
|
|
| Image distortion | ||
1. Image distortion, | NO | Vertical skew copy adjustment | |||
Horizontal skew copy adjustment | |||||
center shift check |
| ||||
| Center shift: | ||||
|
|
| |||
|
|
| Lens center shift adjustment | ||
| YES |
|
|
| |
|
|
|
| ||
|
|
|
| ||
|
|
|
|
| |
|
|
|
|
|
2.Normal (x 1.00), zooming (x 2.00) resolution (focus)
check
YES
| Resolution (focus) adjustment | ||
NO | Normal: Adjust with the No. 4/5 | ||
mirror adjustment screw. | |||
| |||
| Zooming: Adjust with the zooming | ||
| cam. | ||
|
|
| |
|
|
|
3. Normal copy |
| Copy magnification ratio adjustment | |||
NO | Vertical copy magnification ratio | ||||
magnification ratio | |||||
adjustment | |||||
(vertical, horizontal) |
| ||||
| Horizontal copy magnification | ||||
check |
| ||||
| ratio adjustment | ||||
|
|
| |||
| YES |
|
|
| |
|
|
|
| ||
|
|
|
| ||
|
|
|
|
| |
|
|
|
|
|
4. Exposure balance,
Exposure balance adjustment
Blank lamp position adjustment
blank lamp position, lead edge variation check
NO
Copy lead edge adjustment (Including the void area adjustment.)
YES
END