[10]SERVICING AT MEMORY TROUBLE AND MAIN CONTROL PWB RE- PLACEMENT

1. General

The EEPROM in the control PWB and the EEPROM are storing various set values, adjustment values, and counter values.

These data are very important and used for operating the machine properly and for service control.

In the following cases, therefore, various set values, adjustment values and counter values must be set again.

*When memory trouble (U2) occurs.

*When the EEPROM in the main control PWB is replaced.

*When the main control PWB is replaced.

When "U2" trouble occurs, the data cannot be relied upon, and they must be set properly.

2. Purpose

The purpose is to reset the memory data to operate the machine properly.

Use the attached service memory data recording sheet to memorize the newest data when servicing in order to cope with the above situations. This improves efficiency in servicing and realizes quick recovery.

3. Remedies

Perform the procedures according to the following flowcharts. "Sim" in the flowchart means "Simulation."

Memory trouble

Procedures for memory trouble, main control PWB replacement, and main control PWB EEPROM replacement

"U2" trouble occurs

Repair the defective section

NO

Do you replace

 

 

the main control

 

 

PWB?

 

 

 

YES

 

 

 

 

 

 

Replace the main

 

 

control PWB

 

 

 

 

 

 

 

 

 

 

Cancel "U2" trouble

 

 

with simulation 16

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the main

control PWB

Is the

NO

EEPROM in the main control PWB defective?

YES

Replace the main control PWB

1

Replace the

EEPROM in the

main control PWB

Mount the EEPROM of

 

 

 

 

 

 

the old main control to

 

Replace the EEPROM

the new main control

 

 

 

 

 

 

 

 

 

 

 

 

 

End

 

 

 

 

 

 

 

 