Sharp SF-1120, SF-1020 service manual SEC Secl Seeg SUK SCA, Off

Models: SF-1120 SF-1020

1 140
Download 140 pages 48.95 Kb
Page 100
Image 100

Main code

Sub code

 

 

 

 

 

Content

 

 

 

 

 

 

 

 

 

26

06

Destination setting

 

 

 

 

 

 

Used to set the destination (Japan, SEC, etc.).

 

 

When this simulation is executed, the currently set destination is displayed on the copy quantity display.

 

 

Enter the set value and press the PRINT button to store it.

 

 

 

 

 

 

 

 

 

 

 

 

Set value

Destination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

Japan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

SEC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

SECL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

SEEG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

SUK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

SCA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

EX inch series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

EX AB series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

EX inch series (FC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

EX AB series (FC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

Taiwan/China

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07

Drum sensitivity setting

 

 

 

 

 

Used to set the drum sensitivity.

 

 

 

 

 

When this simulation is executed, the currently set drum sensitivity is displayed on the copy quantity display.

 

 

Enter the set value and press the PRINT button to store it.

 

 

 

 

 

 

 

 

 

 

 

 

Set value

 

Drum sensitivity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1

 

 

 

 

 

 

 

 

 

Initial value

 

 

 

2

 

2

 

 

 

 

 

 

 

 

 

 

 

 

3

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

AE original density setting

 

 

 

 

 

Used to set the original density.

 

 

 

 

 

When this simulation is executed, the currently set original density is displayed on the copy quantity display.

 

 

Enter the set value and press the PRINT button to store it.

 

 

 

 

 

 

 

 

 

 

 

 

Set value

 

Original density

 

 

 

 

 

 

 

 

 

Initial value

 

 

 

0

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Thin original

 

 

 

 

 

 

 

 

 

 

 

 

When a dark original is copied in the AE mode, the lead edge (about 4mm) is not copied. If it is necessary to copy

 

 

the lead edge, set this simulation to “1.”

 

 

 

 

 

 

 

13

Warm-up mode setting

 

 

 

 

 

Used to set the main motor operation mode during warm-up.

 

 

When this simulation is executed, the currently set warm-up mode is displayed on the copy quantity display.

 

 

Enter the set value and press the PRINT button to store it.

 

 

 

 

 

 

 

 

 

 

Set value

 

 

Warm-up mode

 

 

 

 

 

 

 

 

 

Initial value

 

 

 

0

 

Normal mode

 

 

 

 

 

 

 

 

 

 

 

 

1

 

The main motor rotates until warm-up is completed.

 

 

 

 

 

 

 

 

 

 

18Toner save mode setting (Japan/SUK only) Used to set ON/OFF of the toner save mode.

When this simulation is executed, the currently set value is displayed on the copy quantity display. Enter the set value and press the PRINT button to store it.

Set value

Toner save mode

 

 

 

Initial value

0

ON

 

 

 

1

OFF

 

 

 

 

8 – 10