(2) User simulation

 

 

 

 

 

Paper jam/Maintenance/

Copy

Copy

 

 

 

 

 

Mini maintenance/

Simulation procedure

State

quantity

button

Paper supply/Toner supply/

 

 

 

 

 

display

LED

 

 

 

 

 

Warning LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Press

the

tray

selection

User simulation input is allowed.

Blink

 

 

OFF

key for 5 sec or more.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Enter

the

simulation code

Selection of simulation code No.

Blink

1

 

ON

No. with the10-key pad.

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Press the COPY button.

Determination of simulation code

Blink

1

1

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Enter

the

selection code

Selection of simulation code menu

Blink

1

2

ON

No. with the 10-key pad.

 

 

 

 

 

 

 

 

 

 

 

 

5. Press the COPY button.

Determination of simulation code menu

Blink

1

2

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Press

the

tray

selection

Escape from user simulation.

 

Returns to

 

key.

 

 

 

When this key is pressed during selection of user

OFF

the copy

 

 

 

 

simulation, the mode returns to 1 (User simulation is

quantity

 

 

 

 

 

 

 

 

 

 

 

 

 

display.

 

 

 

 

 

 

allowed.).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Press the clear key.

(Use this key in case of erroneous input)

 

 

 

 

 

 

 

 

After setting the program, when this key is pressed, the

Blink

 

 

OFF

 

 

 

 

next program input is allowed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(

: Blink)

(3) User simulation code table

Program

Sim.

Selection code:

Factory

code

Set content

setting

 

 

 

 

 

Auto clear passing time

 

[0]: Cancel

 

setting

 

[1]: 30 sec

 

 

[1]

[2]: 60 sec

2

 

 

[3]: 90 sec

 

 

 

[4]: 120 sec

 

 

 

 

 

Pre-heat mode setting and

 

[0]: Cancel

 

passing time setting

 

[1]: 1 min

 

 

[2]

[2]: 15 min

2

 

 

[3]: 60 min

 

 

 

[4]: 120 min

 

 

 

 

 

Auto power shut off mode

 

[0]: Cancel

 

setting and passing time

 

[1]: 5min

 

setting

[3]

[2]: 15 min

2

 

[3]: 30 min

 

 

 

 

 

[4]: 60 min

 

 

 

[5]: 120 min

 

 

 

 

 

Program

Sim.

Selection code:

Factory

code

Set content

setting

 

 

 

 

 

Auto pre-heat control mode

[4]

[0]: Cancel

0

setting and cancel

[1]: Setting

 

 

 

 

 

 

Auto document feeder

 

[0]: Cancel

 

manual document feed mode

[5]

[1]: Setting

0

setting

 

 

 

 

 

 

 

Sorter take-out mode

[7]

[0]: Cancel

1

 

[1]: Setting

 

 

 

 

 

 

 

Auto paper selection

[8]

[0]: Cancel

1

 

[1]: Setting

 

 

 

 

 

 

 

Auto tray selection

[9]

[0]: Cancel

1

 

[1]: Setting

 

 

 

 

 

 

 

(4) Department counter setting content (Set with user program P10 P15)

 

Function name

Setting content

Factory setting

 

 

 

 

P10

Department counter

The department counter is set or canceled.

Cancel

 

setting/cancel

 

 

 

 

 

 

 

 

P11

Department No. registration

The department number is registered. Up to 20 departments can be

No setting

 

 

registered.

 

 

 

 

 

 

 

P12

Department No. change

The registered department number is changed.

No change allowed.

 

 

 

 

P13

Department No. delete

The registered department numbers are deleted.

No delete allowed.

 

 

One department number or all the department numbers can be deleted.

 

 

 

 

 

 

 

P14

Copy quantity display (Total)

The copy quantity of each department is displayed.

No display allowed.

 

 

The count is made up to 50,000. After that, the count starts from 0 again.

 

 

 

 

 

 

 

P15

Copy quantity delete (Total delete)

The counted copy quantity is deleted.

No display allowed. (*)

 

 

One department or all the department can be deleted.

 

 

 

 

 

(*): Because of no registration of department No. at all.

8 – 21

Page 111
Image 111
Sharp SF-1020, SF-1120 service manual User simulation code table, Led