SMC Networks SMC8624/48T manual Appendix B Troubleshooting, Table B-1. Troubleshooting Chart

Models: SMC8624/48T

1 556
Download 556 pages 10.96 Kb
Page 541
Image 541

APPENDIX B

TROUBLESHOOTING

 

Table B-1. Troubleshooting Chart

Symptom

Action

 

 

Cannot connect using

• Ensure that you have configured the agent with a valid IP

Telnet, Web browser,

address, subnet mask and default gateway.

or SNMP software

• If you are trying to connect to the agent via the IP address

 

for a tagged VLAN group, your management station must

 

include the appropriate tag in its transmitted frames.

 

• Check that you have a valid network connection to the

 

switch and that the port you are using has not been disabled.

 

• Check network cabling between the management station

 

and the switch.

 

• If you cannot connect using Telnet or SSH, you may have

 

exceeded the maximum number of concurrent Telnet/SSH

 

sessions permitted. Try connecting again at a later time.

 

 

Cannot access

• Ensure that you have set the terminal emulator program to

the on-board

VT100 compatible, 8 data bits, 1 stop bit, no parity, and set

configuration

the baud rate to any of the following (9600, 19200, 38400,

program via a serial

57600, 115200 bps).

port connection

• Check that the null-modem serial cable conforms to the

 

 

pin-out connections provided in the Installation Guide.

 

 

Forgot or lost the

• Contact SMC Technical Support for help.

password

 

 

 

B-1

Page 541
Image 541
SMC Networks SMC8624/48T manual Appendix B Troubleshooting, Table B-1. Troubleshooting Chart