Page 164 of 378 Install and configure ITG ISL Trunk node
553-3001-202 Standard 1.00 April 2000
Install NTMF94EA and NTCW84KA cables
The ITG Trunk 2.0 card supports a one-cable solution for access to the
T-LAN, E-LAN and serial E-LAN Ethernet Po rts. The E-LAN suppo rts
10BaseT operation and the T-LAN supports 10/100BaseT operation. If you
use for 100BaseT operation on the T-LAN interface, you must install a
NTCW84JA 50-pin I/O panel filter connector block to replace the standard
I/O connectors provided.
Cables that are provided for the E-LAN and T-LAN interface functions
include:
t he NTMF94EA E-LAN, T-LAN, and RS232 Port c able (for non-DCHIP
cards)
t he NTCW84KA E-LAN, T-LAN, RS232 and DCH Ports cable (for
DCHIP cards)

Install the NTCW84KA cable (for DCHIP cards)

1Connect the NTCW84KA cable see to the I/O panel connector (see
Figure 24).
Note:
Make sure to connect to the I/O panel connector that
corresponds to the left slot number of the DCHIP card.
2Secure the mounting screw provided on t he top o f the Sh ielded 25 -Pair
Amphenol Connector to the I/O Panel filter conne ctor in ord er to tie the
shield of the LAN cable to the Meridian1 frame ground for EMC
compliance.