Install and configure ITG ISL Trunk node Page 197 of 378
ITG Trunk 2.0 ISDN Signaling Link (ISL) Description, Installation and Operation
bEnter the Management MAC address. It is the motherboard
Ethernet address. You can find it on the f aceplate l abel of th e card
you are currently configuring. It is also ident if ied as lnIsa0 on the
card startup messages and by the ifShow command in the ITG
shell.
The Management LAN Node IP and Management gateway IP
addresses on the General tab and the Management IP address for
Leader 0, Leader 1 and all Follower cards o n the Card Confi gur ation
tab must be on the same Voice/Management E-LAN subnet.
5Enter the Card TN. For Large Systems, card TNs are validated for
loop, shelf and card separated by da shes. For Smal l Systems, only t he
card number is required.
6Select the Card Density from the drop-down list box: 24 ports for
NT0961AA; 8 ports for NTCW80.
7Enter the ISL D-channel logical device number. Its range is 0-255 for
Large Systems; 0-79 for Small Systems.
8If the card will be a DCHIP card, check the DCHIP is on this Card
check box. The DCHIP card must have an NTWE07AA DCHIP PC
Card with an NTCW84EA Pigtail cable installed and must be
connected to the ISL DCH port on the MSDL or SDI/DCH card.
Note:
The standard configuration is to put the first DCHI P on Leader
0 and the second DCHIP on Leader 1. Additional DCHIPs can be put
on Follower card s.