Page 242 of 378 Upgrade an ITG Trunk 1.0 node to support ISDN signaling trunks
553-3001-202 Standard 1.00 April 2000
5Click the Start Transmit button.
Monitor progress in the Transmit control window. Confirm that the
card software is transmitted successfully to all the 8-port ITG Trunk
cards. The window identifies the cards by their TNs.
If the message in the control window indic ates t he so ftwar e trans mit i s
unsuccessful, do not press Cancel. Leave the Transmit Control
window open displaying the location of the software file on MAT.
If you can Telnet to the card from MAT, but MAT shows the ca rd status
as Not Responding, MAT ITG SNMP MIB is incompatible with the ITG
8-port software version. In this case, the software upgr ade must be
executed from the ITG shell CLI of each 8-port card in the node (see
step a and Figure 44).
a. ITG> swDownload "IP address of MAT
PC","itguser","itguser","","ITG28xx.mms" where xx indicates the
latest version of the ITG Trunk 2.0 software for the 8-port card.
Note:
Be sure to hit the space bar after you type in swDownload and
enter the quotation marks, commas exactly as described in the step
above and shown in Figure 44.
Figure 44
Software download example
MAT PC IP address MAT FTP
Server User ID
MAT FTP
Server password
Null source path Software file name