Upgrade an ITG Trunk 1.0 node to support ISDN signaling trunks Page 241 of 378
ITG Trunk 2.0 ISDN Signaling Link (ISL) Description, Installation and Operation
3Press Enter.
4The ITG shell outputs value = 0 = 0 x 0 to indicate successful
completion of the setLeader command. If the ITG shell outputs
command not found, check the spelling of the command. If the ITG
shell outputs a value of -1, contact Nor tel Networ ks customer technical
support.
5Return to the MAT IP Telephon y G a teway - ISDN IP Trunk Main
window.
6Telnet to Leader 1 and Follower cards in the node.
7Log into the ITG shell.
At the ITG>prompt, enter clearLeader “xxx.xxx.xxx.xxx”,
“yyy.yyy.yyy.yyy”, ”zzz.zzz.zzz.zzz”
(see notes in step 2). The ITG shell outputs value = 0 = 0 x 0 to
indicate successful completion of the clearLeader command.
Note:
You enter clearLeader command even when you remove
configuration files from Follower cards.
Step 2 - Transmit ITG Trunk 2.0 software to the 8-port cards
1Launch MAT/OTM 1.1. Double-click on ITG M1 IP Trk in the Services
folder
1In the IP Telephony Gateway window, select Leader 0 from the ITG
trunk node you are upgrading.
2Select menu Configuration | Synchronize | Transmit. The
ITG-Transmit Options window appears.
3Make sure to set the radio button to Transmit to selected nodes.
Check the Card Software check box only.
4Locate the ITG28xx.mms software file on the MAT PC. If you kn ow the
path to the ITG28xx.mms software file software, type the path
information in the Software field. Or click the Br owse butt on to f ind and
select the file and click the open button in the Browser so that the
software path and filename appear in the Software field in the
ITG-Transmit options window.