Page 246 of 378 Upgrade an ITG Trunk 1.0 node to support ISDN signaling trunks
553-3001-202 Standard 1.00 April 2000
How to upgrade software using the ITG shell

Use this procedure if MAT displays a Card status of Not Responding.

1Prepare the MAT ITG FTP server to find the software image file whe n
it is requested from the ITG card BIOS shell using the upgrade or
swDownload command.
2Select Synchronize | Transmit from the MAT ITG ISDN IP Trunk
application Configuration menu.
3Check the box for Card Software. Browse for the software image file
on the MAT PC. When you find the software image file, open it from
the Browser so the path and file n ame appear in the MAT ITG Trans mit
window.
4Leave the radio button default setting of Transmit to selec ted nodes.
Check the Node Properties, Card Properties and Dialing Plan
check boxes.
5Click the Start Transmit button.
Monitor progress in the Transmit Control window. Confirm that the
Node Properties, Card Properties and Dialing Plan are transmitted
successfully to the Leader 0 ITG Trunk card TN. At this point, it is
normal for transmission to Leader 1 and Follower cards to fail .
6When the transmission is complete, click the Close button .
7Reboot the Leader 0 ITG card.