Page 172 of 378 Install and configure ITG ISL Trunk node
553-3001-202 Standard 1.00 April 2000
Meridian 1 Small System cable installation (Option 11C andOption 11C Mini)
1Set the switches and jumper plugs in the NTAK02 SDI/DCH card as
shown. See Tables29 and 30.
2Connect the NTAK19FB Quad Serial I/O SDI/DCH Cable (or
equivalent) to the I/O connector for t he car d slot in whic h the SDI/DCH
card is installed.
3If the DCHIP card is installed in the main cabinet with the SDI/DCH
card then use NTWE04AD SDI/DCH Extension Cable (1 ft.) from the
NTCW84KA DCH (P5) connector to the NTAK19FB D-Channel port
connector for Port 1 or Port 3.
Table 29
NTAK02 SDI/DCH switch settings for ITG ISL Trunk DCHIP
Port 1 S W 1-1 SW 1 - 2
DCH OFF OFF
Port 3 S W 1-3 SW 1 - 4
DCH OFF OFF
Table 30
NTAK02 SDI/DCH jumper settings for ITG ISL Trunk DCHIP
Port Jumper
location
Strap
for
DTE
Jumper
location RS422
Port 1 J7 C - B J9 C - B
J6 C - B J8 C - B
Port 3 J4 C - B J2 C - B
J3 C - B J1 C - B