Page 354 of 378 Appendix B: Environmental and electrical regulatory data
553-3001-202 Standard 1.00 April 2000
Mechanical conditions

Refer to Table66 for ITG mechanical tolerance ranges.

Storage

Recommended -50° C+70
° C
Relative humidity 0% 95% (non-condensing)

Temperature shock

In three minutes -50° C25
° C
In three minutes 70° C25
° C
Table 66
ITG mechanical specifications
Specification Minimum Maximum

Mechanical

Operating 5-200 Hz 0.1 g Two hours per axis
Non-operating 5-100 Hz 0.5 g
100-200 Hz 1.5 g 30 min. per axis
30 min. per axis
Shock:
Handling
(Packs, unpackaged) Free fall onto each
face and corner See IEC 68-2-31 ,
Tes t E c
Bounce 1.2 g, 30 min/surface See IEC 68-2-31
Tes t E b
Handling
(Packs, packaged) Free fall onto corner,
3 edges, all surfaces See NSTA Proj 1A
Earthquake NEBS GR-63-CORE, Zone 4
Table 65
ITG temperature and humidity specifications (Continued)
Specification Minimum Maximum