Page 364 of 378 Appendix D: Configure a Netgear RM356 modem router for remote access
553-3001-202 Standard 1.00 April 2000
16 Under "Telco Options" toggle
"CLIDAuthen=None/Preferred/Required".
CLID requires a C.O. line subscri bed for CLI D service where avail able.
"Preferred" means some dial-in user profiles may requir e CLID, but
others may not. "Required" means no dial-in call is connected unless
CLID is provided and user profiles require CLID for authentication.
Under "PPP Options" toggle "Recv Authen=PAP". Windows 9x Dial up
Networking (DUN) is not compatible with CHAP/PAP or CHAP on the
modem router: calls are disconnected after a few minutes.
Toggle "Compression=No". Windows 9x DUN is not compatible with
software compression on the modem router: calls are randomly
disconnected.
Toggle "Mutual Authen=No".
Under "IP Address Supplied By:" Toggle "Dial-in User=No", "IP
Pool=Yes". For "IP Start Addr=" type in the E-LAN IP address that will
be assigned to the Dialup Networking ( DUN) PPP client on the r emote
MAT PC.
Note:
The remote MAT PC will receive this E-LAN IP address
whenever DUN makes a dial-in PPP connection to the modem router.
As long as DUN remains connected to the modem router, IP
applications on the remote MAT PC function as if the PC wer e locat ed
on the customer's E-LAN.
Under "Session Options" configure input and output fil ter sets
according to the customer's IP network security policy and practices.
The default setting is no filter sets. Set "Idle Timeout=1200" seconds
to provide 20 minutes idle timeout disconnect for remote support
purposes.
Press Enter to confirm and save data to ROM.
17 Enter menu selection number 14, "Dial-in User Setup", under the
"Advanced Applications" section.
"Menu 14 - Dial-in User Setup " is displayed.
Note:
Up to eight dial-in user profiles may be defined accordi ng to the
customer's network security policy.
18 Enter menu selection 1 to edit the first dial-in user profile.